Description
The condenser coils located within the heat removal section of the Evaporative Air conditioning system, ensure the air onto the coil is always pre-cooled to the wet bulb temperature of the ambient.It considerably increases the efficiency when compared to traditional condenser system.
The combination of this innovative Indirect direct evaporative cooling with Mechanical air conditioning result in best performance with highest energy efficiency and minimised operating costs.
Its area of operation include industrial spaces ,factories,commercial offices ,server rooms / UPS rooms,data centres and industrial processes that require stringent temperature and RH control.
Benefits:
- Air Conditioner with benefits of evaporative cooling
- 100% fresh ,healthy ,clean & cool air
- Weather Proof Cooling Equipment
- Works equally well during Monsoon or in humid areas
- Automatically switches to desired cooling mode as per preset Space conditions
- Substantial savings in TR as it works on Air Conditioning mode only during select period of year
- Most Energy efficient -consumes upto 60 % less power
Features:
- Compact Design
- Indirect Direct Evaporative Cooling system with integrated Dx system within the same foot print
- AMCA certified Centrifugal Blowers for high static and longer air throw
- Custom design DX/CW coil for high cooling efficiency
- Upto 60% saving in running / operating cost
- Energy Efficient IP -55 protected ,IE-3 efficiency ,VFD compatible Electric Motors
- Industrial Grade controller with wired remote
- Wet bulb efficiency upto 130%
- 10 micron filtration (custom design filtration available)
- Suitable for comfort cooling and industrial processes where stringent temperature and RH control is required.
- Capacities upto 40000 CFM
Technical Specifications:
SPECS/MODEL | HAC 5K-10T |
---|---|
Discharge Type | Side |
Airflow ( CMH / CFM ) | 8400 / 5000 |
Static Pressure (mmwg) | 30 |
Motor Make | ABB / Siemens / crompton |
Motor specification | IP-55 Protected,IE2/IE3 Efficiency,TEFC ,4P |
Blower Motor Power (kw/HP) | 1.5/2.0 |
Power Resource (V/Hz) | 415/50 |
Fan Type | AMCA certified Centrifugal Blower |
Fan Speed | 3-phase, single-speed |
Evaporative Media | Cellulose pad of 200mm thk -7mm flute ht/100 mm-thk-5mm flute ht |
Cooling coil | CW / DX |
Low Water Sensor | Yes |
Controller | Industrial Grade Controller (Components from siemens/schnieder) |
Remote | Corded remote with on/off ,pump,blower switch |
Filtration | Panel filter of 90% efficiency down to 10/20 microns |
Tank Capacity (Litre) | 130 |
Evaporation Efficiency | 85% |
EVAPOLER® Hybrid Air Conditioner: The AC WITH BENEFITS OF EC
EVAPOLER® Hybrid AC v/s AC
Power savings per 100 Sq ft per Annum
TYPE | Evapoler®HYBRID AC | AC |
---|---|---|
Covered Area | 100 SQ FT | 100 SQ FT |
Electric Power per 100 SQ FT | **0.796 kw | *1.1 kw |
Electricity Unit Consumption during SUMMERÂ (**12 hrs, 180 days) | ***445.0kw | 2376.0kw |
Electricity Unit Consumption during MONSOONÂ 12 hrs, 90 days) | 859.7 kw | 1188.0 kw |
Electricity Unit Consumption during WINTER(12 hrs, 90 days) | ****162.0 kw | 1188.0 kw |
Total Electricity Consumption Per Year | 1466.7 kw | 4752.0 kw |
Total Electricity Cost per year(INR.) (Assuming Rate @ Rs 8/Unit) | Rs. 11,733.60 | Rs. 38,016.00 |
Saving on Electricity Cost per year ( INR) | Rs. 26,282.40/- | Nil |
% Saving in Running Cost | 69 % | NIL |
*1 TR =100 sq ft=1.1 kw*** only Blower +pump [email protected] 2.06 Kw per 1000 sft **** Ventilation mode-only Blower [email protected] kw per 1000 SFT **Installed Electric power of Hybrid AC per 1000 SQ FT [(1.5+.35+.15+.06)=2.06+5.9=7.96kw.]
Evapoler Hybrid Air Cooling unit is best suited for high humid areas like Jamnagar , Rajkot, Chennai ,Vishakhapattnam ,Mumbai, Cities of Assam like Guwahati,Jorhat ,Cities of Madhya Pradesh like Indore etc